Kds K-92mb 900p Monitor User Manual

Posted : admin On 23.12.2020
Kds K-92mb 900p Monitor User Manual 7,5/10 3755 votes
  1. Kds K-92mb 900p Monitor User Manual Pdf
  2. Kds K-92mb 900p Monitor User Manual Instructions
  3. Kds K-92mb 900p Monitor User Manual User

Table 16-4 KDS Controller Fields

Fields and OptionsDescription

1 - Prevent Chit Bump on Expo Display if Chit Exists on Prep Display

Select this option to prevent a chit from being bumped from an Expo Display if the chit still exists on one of the Prep Displays.

2 - Display Next Course after Previous Course Complete

If the property is using dining courses, select this option to show one course at a time on Kitchen Display Systems (KDS). That is, menu items from course 2 appear on KDS Displays only after menu items from course 1 are bumped.

Antares autotune vst crack. 3 - Show Only Active Orders

Select this option to allow a Speed of Service (SOS) Display to show only tables that have open orders.

4 - Expo-only Items Display as Done

Select this option to change the status of menu items that do not go to Prep Stations to Done when they fire.

5 - Exclude CAL Updates from Service Host Change

If the property does not use the Client Application Loader (CAL), select this option to exclude updates to CAL for Service Host changes made in the KDS Controller.

6 - Enable Item Started Timings

If the KDS is not using Dynamic Order Mode (DOM) and is configured to show every item in an order on separate chits (select Order Devices module option 3 - Single Item Per Sub-Order), select this option to have the application recalculate an order’s target done time (TDT) when the kitchen staff starts on the item with the longest prep time.

After the application recalculates the TDT, the system adjusts all of the fire times for the remaining items (based on individual prep times) to ensure that all items complete at the new TDT.

7 - Include Theme In The Device Name

Select this option to have the KDS Display the current Kitchen Theme after the name of the device on the KDS status bar.

8 - Enable load balancing

Select this option to turn on KDS load balancing for the KDS Controller.

Load balancing distributes new orders to KDS Prep Stations based on which station has the least number of items. KDS Prep Stations are assigned to distribution groups and orders route to the KDS Prep Station with the fewest un-bumped menu items within a distribution group.

9 - Enable Backup Controller Automatic Takeover

If the KDS Controller has a backup service host, select this option to allow the backup KDS Controller to take over automatically when the primary controller is down.

Database Update Frequency

Enter the number of seconds you want the KDS Controller to wait to retrieve the latest updates from the database.

Wait for Prep Suborder

If the property is using dining courses, enter the number of seconds that you want the KDS to wait for Prep Suborders before displaying an expo order as All Prep Done.

Oracle Hospitality recommends entering a value of 1 or 2. The value 0 (zero) does not work with KDS Prep Times.

Media Viewer URL

Enter the uniform resource locator (URL) of the Internet Information Services (IIS) website where you defined the Media Viewer (for example, MyPC:8080).

Number of Zones

Enter the number of kitchen zones to use for collecting food orders.

You can define up to 26 zones. The default value is 0, indicating that zones are not used.

Production Count Increment Type

Select when to add ordered items to the production counter:
  • If you want the application to increase the production counter as soon as workstation operators end the current round of a check, select 1 - Sent from POS.

  • If you want the application to increase the production counter when workstation operators send checks to the KDS, select 2 - Sent (Fired) from EXPO. Oracle Hospitality recommends using this option in a non-DOM environment.

Production Count Decrement Type

Select when to decrease the count of items from the production counter:
  • If menu items appear on two or more prep stations and you want the application to decrease the count when any prep station bumps the item, select First Prep Done.

  • If you want the application to decrease the count when all prep stations bump the item, select All Prep Done. When using this option, you must set all order devices to DOM when the revenue center is in DOM and all order devices to non-DOM when the revenue center is in non-DOM.

  • If you want the application to decrease the count when the Expo station bumps the order, select Expo Done.

Time (sec)

Enter the number of seconds to elapse before automatically bumping all closed orders after reaching the Check Count.

Check Count

Enter the number of checks that are allowed to appear on the KDS before automatically bumping.


Here one can find information about many different types of equipment: tv ( plasma, tft-lcd, widescreen, hdtv ), dvd, vcr, car audio,gsm,digital camera, computer monitors (tft-lcd panels or conventional crt), test equipment, power supplies and many more digital and analogue electronic devices.
There is also datasheet information about integrated circuits diagrams, diodes, transistors, operational amplifiers, pic, pcb design etc.

Kds K-92mb 900p Monitor User Manual Pdf

One can find software, programs, eprom, eeprom, bin files used in equipment repair.
Most files are pdf and djvu formats, zip or rar compressed.
All users may add their files to the system.
Enjoy
Featured Service Manuals Categories
Measuring tools, multimeters > Oscilloscopes Fluke, Hameg, Tektronix
Satellite tv receivers - digital and analogue - Amstrad, Humax, Nokia, Pace
Printers - laser, ink, dot matrix - Canon, Epson, HP
TV - CRT, LCD Projection, TFT, Plasma, Big Screen, HDTV
Cellular phones service manuals - Nokia, Siemens, Motorola, Ericsson, Sony
Power supply for TV, DVD, VCR, Monitor, PC AT ATX
Car schematics > Car audio systems and stereo equipment
Computer equipment > Notebooks , Laptops , PDA
Desktop computers and notebooks > LCD Panels, TFT and CRT Monitor Displays

You can find information for the following makes of equipment (+ many more):Sony, Philips, Grundig, Samsung, JVC, LG, Panasonic, Sharp, Nokia, Daewoo, Blaupunkt, Pioneer, HP, Hitachi, Sanyo, Thomson, Goldstar, Siemens, Ford, Epson, Kenwood, Aiwa, Technics, Clarion, Akai,Hansol, Acer, Funai, Mitsubishi, Telefunken, AOC, Saba, NEC, Vestel, MAG, Universum, Viewsonic, Belinea, Compaq, Loewe, DELL, Canon, IBM, Orion, Hyundai, Eizo, Beko, Proview, Seleco, Yamaha, Mercedes, Casio, Bang And Olufsen, Sampo, Motorola,Becker, Zenith, Roadstar, Finlux, Alpine, Schneider, Salora, TEAC, Ericsson, Samtron, Onkyo, Sagem, Imperial,mitac, optiquest ,dtk, vga, multisynk, trinitron, multiscan, sampo, syncmaster, Fisher, Fujitsu

Here you can find the most popular list of datasheets, schematics and service manuals:

page: 123456

New service manuals on the system
Yihcon [non-polar] NK Ser - 10103003 16Ch-Async-DMA-C - 76361225A Cyber18-20 IO 1 - FG504-IM Tektronix - Korg X-911 Service Manual - 464A Manual . Various - hfe pioneer ct-339 s310 s - cx-5312wt cx558wt chassis - 22GF332 Philips - hfe denon dn-780r service - Installing-Hard-Drive-26 - r6015anj Rohm - 98613-90051 Basic4.0 Lang - hpj nov70 HP - 64709300rL SMD FlatCable - sony ms01 . Various - 323 Tektronix - philips amplifier 22ah302 - pioneer a-602r a-702r sm - AVR1913E3 AVR2113ALL SM V - HP 3455A Operating Agilen - 600 Technical Reference M - 22rh701 Philips - Service Manual 22AH468 Ph -

Kds K-92mb 900p Monitor User Manual Instructions

All service manuals and data sheets, sorted on make and model
Popular Service Manuals and Datasheets searches

Kds K-92mb 900p Monitor User Manual User